Shanghai DDK Scientific Instruments Co., Ltd.
Shanghai DDK Scientific Instruments Co., Ltd.
Products
Benchtop pH Cond DO Meter
  • Benchtop pH Cond DO MeterBenchtop pH Cond DO Meter

Benchtop pH Cond DO Meter

Model:PCD100
The Benchtop pH Cond DO Meter;The measurement of pH 、Cond and dissolved oxygen (DO) in samples covers a wide range of applications including scientific research, industry, environmental monitoring, food, and pharmaceuticals.
• High-resolution LCD display screen
• DO Range: 0-20.00 mg/L
• Cal points: pH: 1-3pts
• Conductivity: 1pt

The core function of the DDKSCI Benchtop pH Cond DO Meter (Model PCD100) is to accurately measure the pH value, conductivity, and dissolved oxygen of samples, while also synchronously detecting mV, TDS, salinity, and resistivity. Widely applicable to scientific research, industry, environmental protection, and other fields, its core highlights are detailed below.


I. Core Functions

Designed specifically for multi-parameter water quality testing, Benchtop pH Cond DO Meter can obtain key indicators such as pH value, conductivity, and dissolved oxygen in one single measurement. Whether testing the acidity and alkalinity of water bodies, the conductivity of solutions, or the dissolved oxygen content in water, it can complete the task with high precision—eliminating the need for multiple devices and significantly improving testing efficiency.


II. Core Advantages

Intelligent & User-FriendlyIts high-resolution LCD screen ensures clear readings. The built-in microprocessor supports automatic calibration (1–3 point calibration for pH, 1-point calibration for conductivity, and full-oxygen or zero-oxygen calibration for dissolved oxygen) and automatic temperature compensation, enabling even beginners to operate it quickly.

Accurate & StableIt delivers precise and stable results with no reading drift: pH accuracy reaches ±0.01pH, conductivity accuracy is ±1.0%FS±1digit, and dissolved oxygen accuracy is ±0.30mg/L.

Durable & Damage-ResistantWith an IP54 dustproof and splash-proof rating, it can operate normally in laboratories or workshops with minor liquid splashes and dusty environments.

Complete PackageIt comes fully equipped with a pH probe, conductivity electrode, dissolved oxygen probe, 3 spare sensor caps, and other accessories, supporting plug-and-play use.


III. Key Technical Specifications

The DDKSCI Benchtop pH Cond DO Meter (Model PCD100) has a wide measurement range:pH: -2.00–20.00pH; Conductivity: 0–200.0mS/cm (auto-ranging); Dissolved Oxygen: 0–20.00mg/LTemperature: Its measurement range is -9.9–130.0℃ and its accuracy is ±0.2℃. It can also do manual salinity compensation and automatic pressure compensation, so it fits different testing environments.It can store 450 sets of data. It also supports USB export and wireless printing.

IV. Applicable Industries & Scenarios

Environmental Monitoring Stations: Can test dissolved oxygen and pH values of river water.

Food Factories: Is used to check the pH and salinity of beverages and sauces.

Scientific Research Laboratories: Works for multi-parameter testing of various samples.

Pharmaceutical Factories: Helps keep the pH and purity of medicinal solutions under control.

Showing real scenario photos can let people see its application effects more clearly.


V. Standard Package Contents

The package includes the PCD100 main unit, ATC pH probe, conductivity electrode, polarographic dissolved oxygen probe, as well as pH buffer solutions, conductivity standard solutions, sensor caps, probe stands, and other accessories. No additional purchases are required—simply assemble the device after unpacking and it is ready for use.


Key Features

1.High-resolution LCD display screen.

2.With built-in microprocessor chip, automatic calibration, automatic temperature compensation, data storage, parameter setup, etc.

3.Automatic calibration, self-diagnosis, automatically recognizing standard buffer solutions,stable reading display.

4.Cal points: pH: 1-3pts; conductivity: 1pt. DO: 100%Oxyegn or Zero oxygen calibration.

5.Each kit comes with an ATC pH probe, a Glass ATC Cond electrode, polarographic type DO probe and 3pcs replaceable sensor caps.

6.IP54 dustproof and spillproof.


Technical Specifications

pH

Range:(-2.00-20.00)pH

Resolution:0.01/0.1 pH

Accuracy:±0.01 pH ±1digit

Cond.

Range:0-200.0mS/cm, auto divided by range of:0-19.99μS/cm; 20.0-199.9μS/cm;

200-1999μS/cm; 2.00~19.99mS/cm; 20.00-199.9mS/cm;

TDS: 0 -100.0g/L, Resistivity:5.00Ω·cm-100.0MΩ·cm, Salinity:0-100.0 ppt

Resolution 0.001

Accuracy ±1.0 % FS±1digit

DO

Range: 0-20.00 mg/L(ppm), 0-200.0 %

Accuracy/Resolution:± 0.30 mg/L; 0.01 or 0.1 mg/L

ATC range :(0 - 50)℃ automatically

Salinity compensation:0~45 ppt manual

Barometric compensation:0~200.0 kPa automatically

Temperature

Range:-9.9 -130.0°C (14.1-266.0℉)

Resolution/Accuracy:0.1℃; ±0.2℃

Data storage:450groups

Data Output

1.USB to Flash Disk

2.Wireless connection to printer (the printer is optional)

3.Power supply:DC12V


Package Contents

Every Benchtop pH mV Cond TDS Sal Res DO Meter kit has the standard parts below. You can use the meter right away with these parts:

1.PCD100 Meter

2.201T ATC pH probe

3.pH buffer solution: pH4.00/7.00/10.01, 50mL, one for each

4.CON201TG Glass ATC Cond probe, K=1.0

5.Standard Cond solution: 50mL: 84μS/1413μS/12.88mS/cm, one for each

6.DO01-2M Polarographic DO probe, cable length: 2m

7.DOS-01 Membrane refill solution: 30mL,1pc

8.DOSC Sensor caps: 3pcs/group, 1pkg

9.F01 Flexible probe holder: 1pc

10.A01 Power adaptor: 1pc

Benchtop pH Cond DO Meter

Hot Tags: Benchtop pH Cond DO Meter, Manufacturer, Factory, Supplier
Send Inquiry
Contact Info
If you have any enquiry about quotation or cooperation, please feel free to email us at rose@ddksci.com or use the following inquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.