The Benchtop Conductivity Meter Touch Screen takes "accurate measurement of solution conductivity" as its core function, and its applications cover basic analysis and quality control scenarios across multiple industries, which are specifically summarized as follows: basic laboratory analysis, water quality monitoring, food and beverage industry, pharmaceutical and biopharmaceutical fields, chemical and industrial production, agricultural and soil analysis, and other industries; it can be equipped with different electrode constants for testing.
• 7" TFT Touch screen
• Range:0~2000.0mS/cm
• Data storage:5000groups
Mainly for precise measurement of solution conductivity, the DDKSCI Benchtop Conductivity Meter Touch Screen (Model EC100T) can test TDS, salinity and resistivity at the same time. It works for basic analysis and quality control in many industries, and gives reliable data support for lab experiments and production processes.
I. Core Functions: Multi-Parameter Detection with Conductivity as the Core
This Benchtop Conductivity Meter Touch Screen's core is high-precision conductivity measurement. It has a measurement range of 0–2000.0mS/cm and an auto-ranging function, so it works for samples with different concentrations. It has the CON201TG glass ATC conductivity probe, and it can automatically compensate for temperature changes to make sure measurement is accurate. The package has three types of standard solutions (84μS, 1413μS, 12.88mS/cm) and a magnetic stirrer. You can debug and use it right after opening the box, no need to buy extra accessories.
II. Core Advantages: Intelligent and User-Friendly for Hassle-Free Operation
Intuitive Touch Operation
It has a 7-inch TFT touchscreen. You can tap lightly to set parameters, and readings show clearly. Even beginners can learn to use it quickly.
Intelligent Calibration
It has a built-in microprocessor chip. It supports calibration guidance and automatic calibration (1-point calibration for conductivity). It also has options for electrode constant calibration or standard solution calibration. It has a self-diagnosis function and can automatically recognize standard buffer solutions, so it reduces operation errors a lot.
Efficient Data Management
It can store 5000 sets of data. It supports data transfer to computers via USB and can connect to printers via Bluetooth. This makes data organization and management efficient.
Robust and Durable
It has an IP54 dust and splash protection rating. It can easily stand small liquid splashes and dust in lab environments.
III. Application Scenarios: Fully Adaptable to Multiple Industries
Basic Laboratories: Used for regular conductivity testing of solutions.
Water Quality Monitoring: Tests conductivity to track water purity.
Food and Beverage Industry: Controls production water quality to make sure products are safe.
Pharmaceutical and Biotech Fields: Monitors conductivity of medicinal solutions.
Chemical Production: Tests solution conductivity to help with process quality control.
Agricultural Soil Analysis: Tests conductivity of soil leachate to support soil improvement.
It can meet testing needs of different industries.
IV. Key Technical Parameters
Conductivity: Measurement accuracy is ±0.5% FS±1 digit, and its auto-ranging range is wide (0–2000.0mS/cm).
TDS: Measurement range is 0–1000.0g/L, and its coefficient can be adjusted.
Temperature: Measurement range is -10.0–135.0℃, accuracy is ±0.2℃. It can precisely adapt to different ambient temperatures.
Data Transmission: It has a computer connection cable, so data transfer is stable and easy.
V. Frequently Asked Questions (FAQ)
Does it support electrodes with different electrode constants?
Answer: Yes. The Benchtop Conductivity Meter Touch Screen can work with electrodes of different electrode constants. You can choose the electrode constant calibration mode during calibration to make it compatible.
What is the function of the magnetic stirrer?
Answer: The stirrer makes sure the sample concentration is even. It prevents measurement errors caused by local concentration differences and improves data accuracy.
Will old data be overwritten when the 5000-set storage is full?
Answer: No. When the storage is full, the instrument will show a "Memory Full" reminder. You have to delete old data before storing new data. This prevents accidental deletion of important data.
With its precise conductivity measurement and easy-to-use touch operation, the DDKSCI Benchtop Touchscreen Conductivity Meter has become a practical tool for quality control in many industries. It helps improve detection efficiency and accuracy.
Key Features
1.With built-in microprocessor chip, intelligent and high accuracy.
2.7" TFT Touch screen, easy reading and operation.
3.With calibration guide, automatic calibration, automatic temperature compensation, data storage, parameter setup, etc.
4.Self-diagnosis functions, automatically recognizing standard buffer solutions.
5.Cond calibration points: 1 pt, supports electrode constant calibration or standard solution calibration.
6. Fast response, stable reading display.
7.The kit comes with an ATC glass cond. probe, standard solution and magnetic stirrer.
8.IP54 dustproof and spillproof.
Technical Specifications
Cond.
Range : 0-2000.0mS/cm, auto divided by range of:
0-19.99μS/cm; 20.0-199.9μS/cm;
200-1999μS/cm;2.00-19.99mS/cm;20.00-199.9mS/cm;
200.0-2000mS/cm(K=10)
match test range: 0-200.0mS/cm
TDS: 0 - 1000.0g/L (TDS factor adjustable);
Resistivity: 5.000Ω·cm-100.0MΩ·cm;
Salinity: 0-100.0ppt
Resolution: 0.001
Accuracy: ±0.5 % FS± one digit
Temperature
Range : -10.0 -135.0℃(14.0-275.0℉)
Resolution/Accuracy : 0.1℃/±0.2℃
Data storage:5000 groups
Data transfer
1.USB stick
2.PC
3.Bluetooth connection to printer (the printer is optional)
Power supply:DC12V
Package Contents
Every Benchtop Touch Screen Cond TDS Sal Res Meter kit has the standard parts below. You can use the meter right away with these parts:
1.EC100T Meter
2.CON201TG Glass ATC Cond probe, (K=1)
3.Standard Cond solution: 50mL: 84μS/1413μS/12.88mS/cm, one for each
If you have any enquiry about quotation or cooperation, please feel free to email us at rose@ddksci.com or use the following inquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy